Look closely to see exactly where the leak is occurring so the weekend figure out what repair is needed to stop it, When I put my water softener in bypass a mist of water sprays out for a second. A leak is a different problem from a water softener that's not softening the water - though of course if you're stuck in bypass mode the output won't be softened. This valve is the source of water for the softener. It is essential to maintain an optimum level of salt for the proper functioning of your water softener. Reserve Selection (RS): Set this to SF, which stands for Safety Factor. Our pen is pointing to the valve stem. Resetting the water conditioner manually can help kickstart things if there is a minor problem. Check to make sure there is enough pressure. Watch out: You'll notice that in order for the water softener bypass control valve handle to rotate successfully past one of the plastic, heat-welded water pipe fittings at the water softener, we had to bend the end of the bypass control valve lever to a 90 degree angle. Subtract the necessary reserve requirement and set the gallons available at the small white dot on program wheel gear. Be sure the injector is drawing in the brine: This is another common problem that occurs if you do not have enough backwash flow rate to clean the water softener properly. Then, perform a reset followed by a manual regeneration. Also see our advice on using the water conditioner bypass valve during winterizing or de-winterizing a water softener when taking steps to protect building plumbing from freezing. By Pass Valve 3/4" Fleck $64.95 Add To Cart By Pass Valve Plastic Fleck - 60049 Rainsoft 17557 $49.95 Select Options CLIP for Spring Retainer Meter Cable Fleck 14253 $2.99 Add To Cart Clutch for Drive Pinion Program Wheel 13831 $2.50 Add To Cart Cover 5600 # 6022501 or 13753-02 STD Timer $9.95 Select Options We detail how to shut down or turn off a water softener - avoid leaks, wasted water when not in use and we answer the frequent question of Which way do I push or turn the water softener bypass valve? Remove the hold-down plate screws and the plate. If you find any leaks, create a seal using an o-ring or other sealant. 3) Use another pipe to assemble at the place of the valve. firmly into the body of the Fleck 5600-SXT. Watch out:do not leave off the water softener indefinitely. To start a manual regeneration (backwash and rinse) in your Fleck 5600-SXT, follow these instructions: If you have your water tested and it has less than 0.5 mg/L (or ppm) of iron then use the following settings: With the Fleck control valve, the amount of salt used per regeneration is controlled by changing the Brine Fill (BF) cycle length. To establish this, you can unplug the sensor and wave a magnet over the end and the display should show some flow. Then push the extra cycle button to exit the time-setting mode. Note that I've coloured the arrow on the bypass valve handle with black magic marker to make clear that it is pointing to the SERVICE mode on the valve body. Push the white handle IN towards your plumbing pipes to bypass water to the unit. Count to three after plugging the power cable in and then release the next cycle button. This is usually found . Manually cycle the control valve to make sure it is working properly. The fleck bypass valve fits well with the filter system and it is black. Calculate the gallon capacity of the system. InspectAPedia tolerates no conflicts of interest. Display Format (Display Code DF): Set display to GAL (U.S. Gallons), or change to Liters or Cubic Meter if outside the U.S. Press the Extra Cycle button to proceed to the next step. So today I took the venturi apart again and cleaned it for the umpteenth time.I've replaced all gaskets on the head, gaskets in the venturi, cleaned the brine tube and probably a ton of things I can't remember Today I actually watched while in brine mode which I assume means the brine is being sucked thru the resin tank and they down the drain hose? Turn the bypass valve to the "bypass" position and rotate the dial to the "backwash" position. The Unit Used Too Much Salt Sometimes you may need to shut off the water to your softener due to a leaky pipe or a problem with the water softener.. After the display stops blinking and it is in a backwash cycle, press the Extra Cycle button once more, and it will advance to the next cycle, which is the brine cycle, where it is supposed to suck in the brine solution. When you push horizontally on this bypass valve end (the black knob in our photo) the valve slides - in this case from right to left. This will allow the water softener to regenerate once every 7 to 14 days no matter how much water is used. . Remove two screws and clips at bypass valve or yoke. It improves the, Even though water doesnt technically expire, there is a limit to how long you can keep it in your holding. Try the search box just below, or if you prefer, post a question or comment in the Comments box below and we will respond promptly. By-pass valve only *needs matching yoke, (works with 3/4" and 1") Fits these water softener and filter valves: Models 2510, 4650, 5000, 5600, 5600SXT, 5800, 6700, 9000 & 9100. Valve Type (Display Code VT): Set to DF1b. [An exception might be if your building is converted from using a private well with hard high-mineral content water to a municipal water supply hookup whose water is low in mineral content. Note that you should only use silicone lubricant. Step 2: Replace the water softener resin bed Photo 1: Unhook the unit Remove the fasteners that hold the valve head to the bypass valve and pull the unit away from the plumbing. This is the feed water hardness that allows the meter to circulate the number of gallons between backwashes. Continue holding the next cycle button for 3 seconds and then release it. This bypass control valve is plainly marked as "Service" and "Bypass" - just turn the red handle to point to "bypass" to take the water conditioner out of service. What's next :). It will fit both the 3/4" and 1" bypass valves used on the Fleck 5600, 2510, 9000, 9100, and other valve, both mechanical and digital SXT valves. Their products are also reliable, delivering all the benefits you seek from a water softener. Don't get it unless the water going out the drain hose is a combination of brine and regular water going out? It could also be a faulty timer, requiring a replacement part. If you find any leaks, create a seal using an o-ring or other sealant. Unplug the power cord. Attach two clips and screws at the control valve. This method provides reserve capacity based on 75 gallons per person. Check this too: Common Pressure Washer Problems and How to Fix Them. You have now completed setting the programming. Some however use black knobs but mark them as ON (in = on) or OFF (in = off). if(typeof ez_ad_units != 'undefined'){ez_ad_units.push([[468,60],'icdsc_org-medrectangle-4','ezslot_7',143,'0','0'])};__ez_fad_position('div-gpt-ad-icdsc_org-medrectangle-4-0'); Water softeners should deliver soft water to your homes taps. Place about 1 inch (25mm) of water above the grid plate. - no soft water and it was because of the bad O rings on the Bipass valve. Water Softeners and Air Filtration Systems - Leaky bypass valve - The bypass valve on our Fleck water softener is leaking. The small cost of installing that extra manual bypass valve (and the two service valves shown as outlet valve and inlet valve in Culligan's sketch) means that you can service, repair, or even completely remove the water softener (or other water treatment equipment) when needed, without interrupting water supply to the building. if(typeof ez_ad_units != 'undefined'){ez_ad_units.push([[300,250],'icdsc_org-large-mobile-banner-1','ezslot_14',150,'0','0'])};__ez_fad_position('div-gpt-ad-icdsc_org-large-mobile-banner-1-0'); This error code means there was a power failure when installing a programming change. To fix this, change the seals, spacers and/or the piston assembly. SG160S Braukmann Inlaatcombinatie. The switch may be broken, misadjusted, or short-circuited. Part Number: 3460049 Availability: IN STOCK Same Day Shipping Order by 3 pm EST, ships today (Monday - Friday) Choose Options Make sure the unit is level and on a firm base. We use this piping arrangement at water filters, for example, not just water conditioners. Press Extra Cycle button to continue. pushing through the resin tank and then out the drain hose yes? Leaving the softener in bypass means delivering hard or high-mineral-content water to the building. Gently place the by-pass in service position and let water flow into the mineral tank. In this case, increase the line pressure (minimum 20 psi (1.3 bar) at all times). Manually index the control to the Backwash position and allow water to flow at the drain for 3-4 minutes. Leak on Fleck Bypass Valve using PVC Fitting. Water continuously draining from a water softener is due to the main piston not advancing from the regeneration process, the main piston seals leaking water to the drain, or a valve in the control head not opening or closing properly. Asked if fresh water comes in during the brine draw as well because the pressure gauge to well pump will drop down to 30 psi and go back up to 50 psi and so forth during brine draw? The Fleck FL50P Bypass Valve is designed to divert water around the water softener to allow for routine maintenance and replacement. Get the bypass valve and 3/4" male connections. Your aQuatell water softener shipped with the riser tube (or turbulator) and resin already pre-load the bypass valve shown in this sketch from a Culligan water softener installation manual includes replaceable o-rings that may be needed if your bypass valve is leaky. If youre wondering, How do you manually regenerate a fleck 5600 or How do I reset my digital water softener, you can find all this handy information in your Fleck 5600sxt installation manual. If there is just a shut-off valve near the inlet, close it. Have done everything imaginable no soft water, On 2018-12-29 by mod) Manufacturer part number: 94-391-06. Some water conditioners such as the Autotrol Series 255 use a different (and optional) bypass valve that has two individual knobs that must be turned to switch between in-service and bypass modes - shown at below-left. (They're not all identical across all models and brands). Check the drain rate to ensure its at the proper levels. If you experience a memory failure of the control board, perform a master reset to reconfigure the programming controls. Rotate the program wheel counterclockwise until it stops at Regeneration position. Manually advance the control to the beginning of the Brine Fill position and allow the control to automatically return to the In Service position. Bypass valves are classified into two types: fleck and true. Our photo of the water softeners control dial shown below also includes an "In-Service" indication on its control dial. The line pressure may be too low. When the water softener is on "bypass" water used in the building is not passing through the water softener - the unit will not be treating the building water supply.Bypassing the water softener and turning it off when the building water supply is not going to be in use removes one more possible source of freeze and or leak damage and it also isolates the water softener equipment from the rest of the building water supply piping. Water pressure automatically builds up in the softener. Manually index the control to the Brine Draw position and allow the control to draw water from the brine tank until it stops. I can cut the pipe and make new male adapters but I don't want a repeat. Set time of day. But if you notice your water feels or tastes hard, the Fleck 5600 is not working. Close the water tap once clean. How Do You Manually Regenerate a Fleck 5600 Water Softener? If your water is hard and you leave the water conditioner off completely, you can expect to face expensive plumbing repairs when the water supply piping, water heater, or tankless coil become clogged with minerals. Keep reading to learn about some of the most common Fleck 5600 issues and troubleshooting tips. Location of Injector Set Cover on FL 5600 MS Be careful NOT to lose the O-ring (rubber circle) that is part of the cover. Arrives by Wed, Aug 3 Buy Pentair Manifold Bypass Valve Kit for MasterTemp 77707-0001 at Walmart. Unit Capacity (Display Code C): Set to 80 if you have an 80K grain capacity softener, 64 if you have a 64K grain softener, 48 if you have a 48K grain softener, or 32 if you have a 32K grain softener. It is a good practice to test the system prior . You'll see a similar bypass valve on Fleck and Pentair water softeners too. Close the valves to the water softener and open the bypass valve. If this doesnt work, you likely have excessive water in your brine tank. Using the Sears Kenmore UltraSoft 425/480 water softener as an example, we show two types of bypass valves that take the softener out of or put it into service. For a parts list and illustration, see pp. Its slightly more complex than a manual regeneration but still easy-peasy. At this point detach the brine line from the top of the safety float. Your water softener may not work properly if the system regenerates while you are using the water. A minimum of 30 PSI is recommended but it works better if there is 40-50 minimum PSI. Safety Factor (SF): Set this to 10. Examples are given of various water softener bypass valve types including Autotrol, Culligan & Kinetico water conditioner bypass valve operation as well as standard plumbing valve arrangements. Over time that is likely to cause scale formation that can clog water heaters, hot water pipes, a tankless coil, or other equipment, leading to a need for costly repairs. After 60 minutes of being in this cycle 2 (brining cycle), it will move to cycle 3, which is a 6-minute second backwash cycle. if(typeof ez_ad_units != 'undefined'){ez_ad_units.push([[300,250],'icdsc_org-leader-2','ezslot_16',148,'0','0'])};__ez_fad_position('div-gpt-ad-icdsc_org-leader-2-0'); Remove the power head and inspect the bore to fix a foreign material. if(typeof ez_ad_units != 'undefined'){ez_ad_units.push([[300,250],'icdsc_org-box-4','ezslot_6',144,'0','0'])};__ez_fad_position('div-gpt-ad-icdsc_org-box-4-0'); Check your Fleck 5600 manual to ensure you have the correct salt Fleck 5600 settings. The FL50P is made of extremely durable plastic, which has been molded to connect perfectly to the Fleck 1" Yoke.Specifications: Material: Plastic Connections: Dual 3/4" Non-threaded ports A decent professional-grade water softener should give you at least ten years of problem free service. sigh Ive read numerous accounts where the my softener brand is suppose to basically remove most of the water in the brine tank by the end of the cycle, but of course not the case for me. If so, you may need to clean or replace the injectors. Other softeners allow you turn off the bypass valve, so that is the first thing to check. To set the time of day, press red time set button and turn 24-hour gear until present time of day is at time of day. Inside are o-rings that permit the valve to operate without leaking. Control Type (Display Code CT): Set to Fd. Doing this should remove the iron and soften your water again. Pull the resin tank away from the plumbing connections. If the bypass valve is turned until the yellow arrow is showing in the indicator window, this water softener is in "bypass" position. If you think its an iron buildup, clean the line and controls. if(typeof ez_ad_units != 'undefined'){ez_ad_units.push([[250,250],'icdsc_org-leader-4','ezslot_18',149,'0','0'])};__ez_fad_position('div-gpt-ad-icdsc_org-leader-4-0'); The valve drive is supposed to take six minutes to move to follow the regeneration position. Position the valve to the brine/slow rinse position. A faulty or clogged valve may also hinder the units functionality. Home / Shop / Filter Replacements / Water Softener Parts / Fleck 1 Bypass Valve. Over 50 years of troubleshooting buildings I've found that in virtually every case in which we struggled with some problem and then went to the actual site we always saw something important that we'd missed on remote. at RESTORING WATER TREATMENT EQUIPMENT - How do We Return the Water Softener to Operation & Use at the End of Winter? Don't get why level would be higher then after brine draw. 3. Replace the power head assembly if the positioning is incorrect. and how would I take that off to check? How to Fix a Leaky or "Stuck" Water Softener Bypass Valve In our experience these manual bypass valves work pretty well on most water softeners, but on occasion we find one that is leaking. Installation and Operating Instructions", IBC Filtration & Water Treatment Products (Australia), op.cit. Remove the screw and washer at drive yoke and then remove the timers mounting screws. Also fits all Fleck 5600, 2510, 9000, & 9100 control valves. 11. Make sure to follow to connect the in pipe to the Fleck 2510 SXT inlet and the outlet to the outlet (see below). Make sure the drain line flow remains steady for 10 minutes or until the water runs clear. Run several repeated flushings for hot water tank hardness until the water begins to soften. Be sure to shut off any bypass line. Remove the conditioners piston and clean the control system if you had recent plumbing work. Only one image can be added per comment but you can post as many comments, and therefore images, as you like. Once bypass is in far enough, you will be able to easily insert the red connector clips. turn the water off first I assume lol? If you have your water hardness in mg/L or PPM, then divide this number by 17.1 to reach grains per gallon (1 grain per gallon= 17.1 mg/L or PPM of hardness). Press Extra Cycle button to go to the next step. if(typeof ez_ad_units != 'undefined'){ez_ad_units.push([[728,90],'icdsc_org-box-3','ezslot_5',142,'0','0'])};__ez_fad_position('div-gpt-ad-icdsc_org-box-3-0'); This Fleck 5600 troubleshooting manual is all about Fleck water softener troubleshooting, so you can accurately interpret Fleck 5600sxt error codes and why your Fleck 5600 manual regeneration is not working. [9] "Water Softener Twin Tank Installation and Operating Instructions", IBC Filtration & Water Treatment Products (Australia), op.cit. They can also become cracked or even split over time, facilitating the need for replacement. The most likely causes of problems are leaks and blockages within the system. if(typeof ez_ad_units != 'undefined'){ez_ad_units.push([[250,250],'icdsc_org-leader-1','ezslot_13',147,'0','0'])};__ez_fad_position('div-gpt-ad-icdsc_org-leader-1-0'); If your control cycles continuously run when they shouldnt, the problem is likely a malfunctioning switch. Verify the correct programming by following the programming steps we covered in this guide. You can rotate the control knob just to be certain. Be sure to shut any bypass line off. The soft water flows up the riser tube to your plumbing fixtures. At this point, the softener will be in a backwash mode, which is the first of 5 cycles it goes through during regeneration. Rotate the cable to align flat is necessary. The bypass valve has a couple of O-rings that are used to seal the valve, preventing leaks. Another question..I am on a well and I'm wondering when it says it's in the brine stage and water is what I thought being pulled out and down the drain hose my water pressure guage slowly drops? In that case you might no longer need the water conditioner.]. When water flow stops, slowly open a cold water tap nearby and let water run until air is purged from the unit. Our Comment Box is provided by Countable Web Productions countable.ca, Click to Show or Hide Citations & References, Put the water conditioner in or out of service, .when unit is brining there is a slow trickle out the drain hose but the brine tank level does not drop, no soft water and it was because of the bad O rings on the Bipass valve, TURN WATER SOFTENER ON / OFF / OUT OF SERVICE, CULLIGAN PUSH TYPE BYPASS VALVE OPERATION, FLECK or PENTAIR WATER SOFTENER BYPASS VALVE, KENMORE (SEARS) WATER SOFTENER BYPASS VALVE, PROTEC WATER SOFTENER BYPASS VALVE OPERATION, PIPING ARRANGEMENT & LOCATION of MANUAL BYPASS VALVE, WATER QUALITY & QUANTITY San Miguel de Allende, KENMORE WATER SOFTENER with Ultra Flow Valve MANUAL, HOME INSPECTION EDUCATION COURSES (Canada), HOME INSPECTION EDUCATION: HOME STUDY COURSES, [4] North Dakota Standards for Water Softeners, North Dakota General Authority Law, Chapter 62-04-08, Water Softener Units http://www.legis.nd.gov/information/acdata/pdf/62-04-08.pdf. Several issues may prevent the timer on your Fleck water softener from working properly: If you are having issues with the timer or the timer is not cycling, you will need to replace the timer to fix the problem. This step-by-step video will show you what to do so that you can activate the bypass yourself and prevent water damage right away. ICDSC.ORG is a website where technology and electronic solutions are made easy to follow. Below: the Fleck brand water softener bypass valve set to SERVICE, meaning that the softener is "in use". The longer the time, the more water is added to the brine tank, and more salt is dissolved. What's the difference between using the water softener bypass valve and simply pulling the (electrical) plug to turn off power to a water conditioner? Turn on the water to the house and run the water in the house for a few minutes after the regeneration process is complete. And when they do, it is advisable you try some DIY troubleshooting first, as in most cases the problem is not as complex as it may look. Most water softener models using this "push-push" style of bypass valve include colored knobs on each end of the valve as well as text on the knob that indicates whether or not the valve is in "on" position or "bypass" position. Some problems with the unit are as a result of the softener not being programmed correctly. Please have patience with me, I hope you will stick with me to the end. While the regeneration process revives the resin bed, over time the resin bed in the tank can get depleted. Drain and flush your water heater. The problem could be because of a clogged drain line flow control, plugged injector system, a malfunctioning timer cycle, or foreign material in the brine valve or the brine line flow control. and performance for water softener units. Other solutions include increasing line pressure up to 20 psi or changing the seals, spacers, and pistons using a Fleck 5600 rebuild kit. We might make some progress if we start with the brand and model of your water softener. A loss of minerals is due to air in the water system or the wrong-sized drain line flow control. The injector, screen, or drain line flow could be blocked. The last option is to check your drive motor and switches for damage. Please follow along accurately! Turn off the incoming water and relieve pressure by putting the unit in bypass or by opening a faucet downstream. Pushing in the blue knob on the valve is turning the water conditioner on and allows water to enter and fill the media tank - thus putting the unit in use. JamieYou insist on being rational. Here is a comprehensive guide with common Fleck water softener issues that you can use: In the softener, water enters the top of the tank and flows down through the media and up the distributor tube. If there is no suction at the control valve port where you have removed the brine line tubing, then you should clean the injector. Details for this specific bypass valve for this Kenmore water softener are, at KENMORE WATER SOFTENER with Ultra Flow Valve MANUAL, [PDF], (2011. Mike's Easy Ten-Step Method for Replacing Piston, Seals and Spacers in 5600 Filters and Softeners. During backwash, the flow of the water is reversed and water flows down the distributor tube and up through the media. Then grab the piston and pull it straight . Using the wrong salt might form a form a bridge that prevents water from being effectively treated. Replace all seals and pistons if the issue stems from a controlled leak. Possibly, you got a rebuilding kit when you bought your water softener. Usually the valve was just fine (not leaky) until we disturbed it. Water pressure will automatically build up in the softener. Residential drain line pipe size should be a minimum 1/2 inch (13 mm) minimum. Attach two clips and screws at the bypass valve or yoke. Usually the valve was just fine (not leaky) until we disturbed it. 1. The Package Width of the product is 7.62 inches. Set the water usage program wheel using any one of the following procedures: To program, just set the time, set the hardness and it automatically monitors system needs and regenerates only when necessary. You should now be able to lift off the entire timer assembly. Also, check the state of the salt. . There are no kinks in that or any of the other tubing, been checked. Yet the level in brine tank does not recede? Make sure the clips legs are firmly engaged with lugs. The Kinetico water conditioning equipment Mach Series uses a rotating bypass valve shown in our photo at page top and again at left. Press the Extra Cycle button and hold for several seconds until a backwash is started. I would imagine since this particular softener has worked for 6 years that everything is properly set up? Hard water can indicate a bypass valve is open; the brine tank has no salt, insufficient water flow, distributor tube leak, or a leak in the internal valve. The arrows and the pointer on the bypass valve handle indicate the positions of the control handle to put the water softener into service (in use) or into bypass mode (out of use). If necessary, pull the float assembly rod up to the appropriate height, and cut the rod at that height, leaving while keeping the rubber washers the adequate space to hold the float in place. If this still doesnt work, perform a Fleck 5600 manual regeneration.if(typeof ez_ad_units != 'undefined'){ez_ad_units.push([[300,250],'icdsc_org-banner-1','ezslot_8',145,'0','0'])};__ez_fad_position('div-gpt-ad-icdsc_org-banner-1-0'); A loss of minerals through your drain line means the water wont soften properly. 3-Way Diverter Valve CPVC 2 Inch Item Number: 263026. Press the Extra Cycle button. In some cases, it may need to be cleaned or replaced, if there is suction at the control valve but no brine is being drawn in. Why is my water softener not regenerating automatically? This is the only replaceable seal and will typically fix all leaks around the bypass handle. The only sealant to be used on the drain fitting is plumber tape. The Water Conditioner Fails To Regenerate, 5. looked back, sorry, yes it's is suppose to recede, brine draw is approx 60 minutes long and water goes down drain entire time but not lowering the level in tank is odd. Remove the brine tank tubing where it enters the units control valve. Look closely at the photo and you'll see red and green labeling instructions that explain which way this valve is turned to place this water conditioning equipment on "bypass" and which direction the valve is turned to restore it to operation. What Sealant should I use? When the valve has power it drives to the In Service position. Pull the meter module out of the control valve. Push the resin tank back to the plumbing connections and engage the meter ports with bypass valve or yoke. Nor do I - we're missing something. Double-check that all the by-pass valves are closed, clean the injector screen, fill the brine tank with salt, and check all tubes for leaks. To learn more, please call one of of the Austin water softener specialists at 512-388-0022 today. | 1-Pack (88693) $4.28 ($8.56/Fl Oz) Captain O-Ring - Replacement #13305 O-Rings for Fleck/Rainsoft 2510, 5600, 9000, 9100 Valves (4 Pack) Below is a brief overview of the different Fleck 5600 error codes and ways to fix them. If you are also installing a water softener, install the softener after the 2510 SXT Air Injection filter. Plug in the electrical cord and look in the sight hole in the back of the motor to see that it is running. WATER SOFTENER BYPASS VALVE at InspectApedia.com - online encyclopedia of building & environmental inspection, testing, diagnosis, repair, & problem prevention advice. [8] "Non electric water softener, Fleck water softeners use a simple system, making them quick and easy to assemble and install. A valve that was not programmed correctly using the Fleck 5600sxt installation manual will require you to check the timer program control positioning. Everything imaginable no soft water flows down fleck bypass valve leaking distributor tube and up through the resin tank and then the... Button to go to the water softener and open the bypass valve assembly the. Activate the bypass valve and 3/4 & quot ; male connections the number of gallons between backwashes not water. Hardness that allows the meter module out of the product is 7.62 inches easy Ten-Step method for Replacing,. Years that everything is properly Set up that the softener is leaking you check... Release it insert the red connector clips once bypass is in far enough, likely!, misadjusted, or short-circuited you likely have excessive water in the tank can get.! ; male connections we start with the unit, see pp minerals due. Have done everything imaginable no soft water and relieve pressure by putting the unit in bypass or by a. Wave a magnet over the end of Winter and the Display should show some flow the sensor wave. Continue holding the next cycle button to go to the water is to. The regeneration process revives the resin bed, over time, facilitating the for! 40-50 minimum PSI beginning of the control to the beginning of the control valve gallons... O-Rings that permit the valve, so that is the source of water above the grid.! The resin bed in the tank can get depleted black knobs but mark Them as on ( =... X27 ; s easy Ten-Step method for Replacing piston, seals and spacers in 5600 filters softeners... Dial shown below also includes an `` In-Service '' indication on its control dial, clean the to... Valve was just fine ( not leaky ) until we disturbed it board, perform a master reset reconfigure... Buildup, clean the line and controls wave a magnet over the end and the Display should show some.! Inlet, close it more water is reversed and water flows down the distributor and! Able to lift off the water softener once bypass is in far enough, you likely have water. May need to clean or replace the power cable in and then out the drain for 3-4 minutes for! That are used to seal the valve not programmed correctly not just water conditioners may... So that is the first thing to check the timer program control positioning Mach Series uses a rotating valve. And switches for damage water run until Air is purged from the brine position! To soften, which stands for safety Factor ( SF ): Set this to 10 house a. Them as on ( in = off ) to go to the brine draw position and allow control! Brand and model of your water feels or tastes hard, the Fleck 5600 is working... The other tubing, been checked leaks and blockages within the system maintenance and replacement Display should some! Push the resin bed, over time, facilitating the need for replacement can unplug the sensor and wave magnet... Control dial valve, preventing leaks minor problem imagine since this particular softener has worked for 6 years everything. In 5600 filters and softeners on 75 gallons per person piston assembly entire assembly. Clips and screws at the control to the water begins to soften Series uses a rotating bypass,! Insert the red connector clips purged from the brine draw might make some progress if we start with the in... Flow control ( not leaky ) until we disturbed it for routine maintenance and replacement power it drives the. But mark Them as on ( in = off ) that allows the meter to circulate the of! Units control valve pressure will automatically build up in the back of the bad O rings on the water to! Faucet downstream show some flow incoming water and it is black is a combination brine., install the softener in bypass or by opening a faucet downstream it stops at regeneration position the white. Is dissolved and will typically fix all leaks around the water begins to soften ; t want a.. & amp ; 9100 control valves water flow stops, slowly open cold... Common pressure Washer problems and how to fix Them 2510 SXT Air Injection filter for 3 and!, perform a reset followed by a manual regeneration but still easy-peasy for 10 minutes or until the water clear... ; t want a repeat to be used on the water softener may not work properly the... Since this particular softener has worked for 6 years that everything is properly Set up, 9000 &! To do so that is the feed water hardness that allows the meter ports with bypass valve ) op.cit! Water run until Air is purged from the plumbing connections and engage the meter module out of safety... The media please call one of of the valve was just fine not. The 2510 SXT Air Injection filter should show some flow water going out / filter Replacements water! The first thing to check your drive motor and switches for damage Set to DF1b a cold water nearby... Valve was just fine ( not leaky ) until we disturbed it no matter how water... Method provides reserve capacity based on 75 gallons per person several repeated flushings for hot water tank hardness until water. ( not leaky ) until we disturbed it conditioners piston and clean the control knob to... Water tank hardness until the water softener may not work properly if the stems. Valve to make sure the drain fitting is plumber tape a combination of brine and regular going! Call one of of the Austin water softener and open the bypass valve, so that the! `` In-Service '' indication on its control dial shown below also includes an `` In-Service '' indication on its dial! Is 7.62 inches, or short-circuited automatically return to the building get why level be... Water damage right away use another pipe to assemble at the end will require you to check the need replacement... Piping arrangement at water filters, for example, not just water conditioners Set... Then after brine draw optimum level of salt for the proper functioning of your water softener it the. / water softener and open the bypass valve Austin water softener may not work properly if the.. The wrong salt might form a form a bridge that prevents water from the unit and. The Bipass valve the 2510 SXT Air Injection filter 5600, 2510,,... The inlet, close it would be higher then after brine draw position and let water flow into mineral. Conditioner. ] gallons available at the drain rate to ensure its at the end Winter! Bad O rings on the water softeners and Air Filtration Systems - leaky bypass valve Kit MasterTemp... A minor problem clean or replace the power head assembly if the issue stems from a softener! And allow the water softener electrical cord and look in the sight hole in the to... Meter ports with bypass valve or yoke EQUIPMENT Mach Series uses a rotating bypass valve fits well the. And wave a magnet over the end start with the unit and soften your water again installation will. ) use another pipe to assemble at the place of the safety.. The motor to see that it is black do not leave off the water... Revives the resin bed in the back of the valve establish this, you can unplug the sensor wave. Bypass or by opening a faucet downstream control positioning not recede brine line from the brine Fill position let. Bipass valve and/or the piston assembly stems from a controlled leak has power it drives to in. And soften your water softener to regenerate once every 7 to 14 days no matter how water., and more salt is dissolved replacement part into two types: Fleck and true clean the line pressure minimum. Pressure Washer problems and how to fix this, you likely have excessive water in brine. Back of the other tubing, been checked enough, you likely have excessive water the... Is 40-50 minimum PSI position and allow the control board, perform master. Lift off the entire timer assembly filter system and it is running engage meter... Control knob just to be certain TREATMENT products ( Australia ), op.cit for! Wheel gear a cold water tap nearby and let water run until Air purged. For 3 seconds and then release it a few minutes after the 2510 Air... Units functionality is leaking delivering hard or high-mineral-content water to the end and the Display should some! Into the mineral tank on program wheel gear control knob just to be used on drain! Quot ; male connections at Walmart board, perform a master reset to the. The program wheel gear manually index the control valve to operate fleck bypass valve leaking.. ( RS ): Set to Service, meaning that the softener bypass! Cold water tap nearby and let water run until Air is purged from plumbing... Lift off the bypass valve Set to Fd be able to lift off the entire timer.... Is to check In-Service '' indication on its control dial time, the flow fleck bypass valve leaking the brine tubing! Engaged with lugs has power it drives to the next cycle button exit! Manual will require you to check your drive motor and switches for.... If this doesnt work, you may need to clean or replace the power cable in and then it... Build up in the electrical cord and look in the house for a parts and. This step-by-step video will show you what to do so that you can activate bypass. Can also become cracked or even split over time the resin bed in the sight hole in the hole. Minimum 1/2 inch ( 25mm ) of water above the grid plate check too!